Show simple item record

dc.contributor.authorHamilton, Martin A.
dc.contributor.authorCollings, Bruce J.
dc.date.accessioned2017-09-26T21:12:17Z
dc.date.available2017-09-26T21:12:17Z
dc.date.issued1991-08
dc.identifier.citationHamilton, Martin A., and Bruce Jay Collings. “Determining the Appropriate Sample Size for Nonparametric Tests for Location Shift.” Technometrics 33, no. 3 (August 1991): 327-337. doi:10.2307/1268784.en_US
dc.identifier.issn0040-1706
dc.identifier.urihttps://scholarworks.montana.edu/xmlui/handle/1/13767
dc.description.abstractFor the case in which two independent samples arc to be compared using a nonparametric test for location shift, we propose a bootstrap technique for estimating the sample sizes required to achieve a specified power. The estimator (called BOOT) uses information from a small pilot experiment. For the special case of the Wilcoxon test, a simulation study is conducted to compare BOOT to two other sample-size estimators. One method (called ANPV) is based on the assumption that the underlying distribution is normal with a variance estimated from the pilot data. The other method (called NOETHER) adapts the sample size formula of Noether for use with a location-shift alternative. The BOOT and NOETHER sample-size estimators are particularly appropriate for this nonparametric setting because they do not require assumptions about the shape of the underlying continuous probability distribution. The simulation study shows that (a) sample size estimates can have large uncertainty, (b) BOOT is at least as accurate as and can be much more accurate than ANPV, and (c) BOOT and NOETHER achieve similar accuracy, although NOETHER is prone to underestimation.en_US
dc.titleDetermining the appropriate sample size for nonparametric tests for location shiften_US
dc.typeArticleen_US
mus.citation.extentfirstpage327en_US
mus.citation.extentlastpage337en_US
mus.citation.issue3en_US
mus.citation.journaltitleTechnometricsen_US
mus.citation.volume33en_US
mus.identifier.categoryEngineering & Computer Scienceen_US
mus.identifier.doi10.2307/1268784en_US
mus.relation.collegeCollege of Engineeringen_US
mus.relation.departmentCenter for Biofilm Engineering.en_US
mus.relation.departmentChemical & Biological Engineering.en_US
mus.relation.departmentChemical Engineering.en_US
mus.relation.universityMontana State University - Bozemanen_US
mus.relation.researchgroupCenter for Biofilm Engineering.en_US
mus.data.thumbpage6en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


MSU uses DSpace software, copyright © 2002-2017  Duraspace. For library collections that are not accessible, we are committed to providing reasonable accommodations and timely access to users with disabilities. For assistance, please submit an accessibility request for library material.