Single cell encapsulation, detection, and sorting of Pseudomonas syringae using drop-based microfluidics
dc.contributor.advisor | Chairperson, Graduate Committee: Abigail Richards; Connie Chang (co-chair) | en |
dc.contributor.author | Lindsay, Travis Carson | en |
dc.date.accessioned | 2023-10-18T15:27:03Z | |
dc.date.available | 2023-10-18T15:27:03Z | |
dc.date.issued | 2023 | en |
dc.description.abstract | Bacteria can survive antibiotic or bactericidal treatment through genetic mutations. Even within bacterial populations that are fully susceptible to treatment, a small proportion of cells can have enhanced survival capacity in a phenomenon called persistence. Traditional microbiology methods can fail to identify or isolate these persister cells present within the population. A novel method for high-throughput single cell analyses of microbial populations is that of drop-based microfluidics, in which individual cells can be isolated within picoliter-sized drops. In this work, fluorescent detection and dielectrophoresis-based sorting of drops was developed for isolating Pseudomonas syringae persister cells following antimicrobial treatment. We demonstrate: (1) the dielectrophoresis-based sorting of dye-filled 25 micron drops based upon two colors, (2) differences between laser-induced fluorescent detection of dyes compared to single bacterial cells, (3) single-cell isolation of P. syringae into 25 micron droplets with ~10% of droplets containing singlecells, and (4) the treatment, staining, and fluorescent characterization of P. syringae at 0.5x, 5x, and 50x the minimum inhibitory concentration of carbonyl cyanide m-chlorophenyl hydrazone (CCCP), an antibiotic which resulted in 6.2%, 10.2%, and 88.6% cell death of the population, respectively. These results provide the groundwork for studying antibiotic-treated P. syringae and the isolation of surviving cells that will lend insight into the molecular basis of persistence for preventing recurrent infections and decreasing the likelihood of antibiotic resistance. | en |
dc.identifier.uri | https://scholarworks.montana.edu/handle/1/17876 | |
dc.language.iso | en | en |
dc.publisher | Montana State University - Bozeman, College of Engineering | en |
dc.rights.holder | Copyright 2023 by Travis Carson Lindsay | en |
dc.subject.lcsh | Pseudomonas | en |
dc.subject.lcsh | Microfluidics | en |
dc.subject.lcsh | Cultures (Biology) | en |
dc.subject.lcsh | Electrophoresis | en |
dc.subject.lcsh | Fluorescence | en |
dc.title | Single cell encapsulation, detection, and sorting of Pseudomonas syringae using drop-based microfluidics | en |
dc.type | Thesis | en |
mus.data.thumbpage | 11 | en |
thesis.degree.committeemembers | Members, Graduate Committee: Ryan Anderson | en |
thesis.degree.department | Chemical & Biological Engineering. | en |
thesis.degree.genre | Thesis | en |
thesis.degree.name | MS | en |
thesis.format.extentfirstpage | 1 | en |
thesis.format.extentlastpage | 88 | en |
Files
Original bundle
1 - 5 of 6
- Name:
- lindsay-single-2023.pdf
- Size:
- 11.66 MB
- Format:
- Adobe Portable Document Format
- Description:
- Single cell encapsulation, detection, and sorting of Pseudomonas syringae using drop-based microfluidics (PDF)
No Thumbnail Available
- Name:
- 1-25-Micron Drop Production.mp4
- Size:
- 15.62 MB
- Format:
- Unknown data format
- Description:
- 25-micron drop production (MP4)
No Thumbnail Available
- Name:
- 2-15 Micron Drop Maker.dwg
- Size:
- 939.01 KB
- Format:
- Unknown data format
- Description:
- 15 micron drop maker (DWG)
No Thumbnail Available
- Name:
- 3-25 Micron Drop Sorter.dwg
- Size:
- 380.18 KB
- Format:
- Unknown data format
- Description:
- 25 micron drop sorter (DWG)
No Thumbnail Available
- Name:
- 4-Sorting Junction During Electrode Testing-converted.mp4
- Size:
- 375.6 KB
- Format:
- Unknown data format
- Description:
- Sorting junction during electrode testing (MP4)
License bundle
1 - 1 of 1