Compact, mid-infrared laser source for remote sensing of gas effluents
dc.contributor.advisor | Chairperson, Graduate Committee: Joseph A. Shaw | en |
dc.contributor.author | Berg, Trenton Jeffery | en |
dc.date.accessioned | 2013-06-25T18:37:48Z | |
dc.date.available | 2013-06-25T18:37:48Z | |
dc.date.issued | 2009 | en |
dc.description.abstract | Remote sensing of gas effluents in the mid-IR wavelength region from 2 microns to 5 microns is preferred due to strong molecular absorption features (10 to 100 times stronger than in the near-IR) and high-transparency atmospheric windows. Currently, long-range mid-IR remote sensing is inhibited by the lack of suitable laser sources. As a result, frequency conversion in nonlinear optical materials has emerged as a powerful method to produce high-power, tunable, mid-IR light. However, compact, high-power narrowband conversion systems suitable for long-range mid-IR spectroscopy are not commercially available. This thesis describes the development of a high-power, narrowband, tunable, compact, mid-IR laser source for long-range remote sensing of gas effluents. Frequency conversion into the mid-IR is achieved by use of a high-peak-power, compact pump laser and optical parametric generation (OPG) in periodically poled nonlinear crystals. This mid-IR laser system was designed and developed for remote sensing at ranges up to and exceeding 100 m in a compact form factor. Such a laser will fill the current scientific need for a hand-held mid-IR laser source capable of long-range mid-IR spectroscopy. Based on theoretical models and experimental demonstrations a compact mid-IR laser source was developed that emits > 1 mJ broadband pulses in the mid-IR. To narrow the linewidth of the broadband OPG output, optical parametric amplification was demonstrated through seeding of the OPG process with a narrowband, continuous-wave, distributed feedback (DFB) laser. Seeding efficiencies exceeding 35% were demonstrated for 1 mJ of output energy, and efficiencies exceeding 65% were demonstrated at lower energies when the pump beam was spatially filtered. The linewidth of the narrowed mid- IR output was inferred to be < 350 MHz based upon heterodyne measurements conducted at the signal wavelength in the near-IR. This linewidth is well within the FWHM bandwidth of typical mid-IR atmospherically broadened molecular absorption features. The demonstrated mid-IR energies and laser linewidths are predicted to be sufficient for detection of low concentration gas effluents (< 1 ppm) at ranges exceeding 100 m. The developed mid-IR laser source was used to successfully demonstrate differential detection of carbon dioxide (CO 2). | en |
dc.identifier.uri | https://scholarworks.montana.edu/handle/1/908 | en |
dc.language.iso | en | en |
dc.publisher | Montana State University - Bozeman, College of Engineering | en |
dc.rights.holder | Copyright 2009 by Trenton Jeffery Berg | en |
dc.subject.lcsh | Lasers | en |
dc.subject.lcsh | Remote sensing | en |
dc.subject.lcsh | Optical radar | en |
dc.title | Compact, mid-infrared laser source for remote sensing of gas effluents | en |
dc.type | Thesis | en |
thesis.catalog.ckey | 1509071 | en |
thesis.degree.committeemembers | Members, Graduate Committee: Wm. Randall Babbitt; Kevin S. Repasky; Peter Roos | en |
thesis.degree.department | Electrical & Computer Engineering. | en |
thesis.degree.genre | Thesis | en |
thesis.degree.name | MS | en |
thesis.format.extentfirstpage | 1 | en |
thesis.format.extentlastpage | 112 | en |
Files
Original bundle
1 - 1 of 1