Comparison of quantification methods for an endoscope lumen biofilm model

dc.contributor.authorHaas, Bruno
dc.contributor.authorJames, Sarah
dc.contributor.authorParker, Albert E.
dc.contributor.authorGagnon, Marie-Claude
dc.contributor.authorGoulet, Noémie
dc.contributor.authorLabrie, Philippe
dc.date.accessioned2024-03-05T21:56:32Z
dc.date.available2024-03-05T21:56:32Z
dc.date.issued2023-12
dc.description.abstractBiofilm has been implicated in multi-drug resistant organism outbreaks following endoscopic procedures. Automated Endoscope Reprocessors (AER) are devices validated to clean and disinfect endoscopes per applicable standards. The ISO 15883 part 4 standard guides performance testing validation of AERs, including cleaning performance using a biofilm test soil. The standard recommends assessment of biofilm reduction using protein or carbohydrate quantification methods. The aim of this study was to assess the suitability of various quantification methods using the ISO biofilm model. The ISO 15883 part 5 biofilm test soil method was used to grow biofilm within lumens representative of endoscopes channels. The biofilm was then quantified using five methods: Crystal Violet (CV), Colony Forming Units (CFU), Total Organic Carbon (TOC), protein assay with Orthophtalaldehyde (OPA), and protein assay by micro bicinchoninic acid (μBCA). The five methods were statistically analyzed for their ability to assess biofilm reduction on samples accurately and precisely. In addition, the quantification methods were compared to demonstrate statistical equivalency, and thus their suitability for assessing biofilm cleaning performance testing of AERs.en_US
dc.identifier.citationHaas, B., James, S., Parker, A. E., Gagnon, M. C., Goulet, N., & Labrie, P. (2023). Comparison of quantification methods for an endoscope lumen biofilm model. Biofilm, 6, 100163.en_US
dc.identifier.issn2590-2075
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/18355
dc.language.isoen_USen_US
dc.publisherElsevier BVen_US
dc.rightscc-byen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en_US
dc.subjectBiofilm quantificationen_US
dc.subjectISO 15883en_US
dc.subjectAutomated endoscope reprocessoren_US
dc.subjectEndoscope lumensen_US
dc.subjectReusable medical devicesen_US
dc.subjectBiofilmen_US
dc.subjectBiofilm cleaningen_US
dc.titleComparison of quantification methods for an endoscope lumen biofilm modelen_US
dc.typeArticleen_US
mus.citation.extentfirstpage1en_US
mus.citation.extentlastpage7en_US
mus.citation.journaltitleBiofilmen_US
mus.citation.volume6en_US
mus.data.thumbpage5en_US
mus.identifier.doi10.1016/j.bioflm.2023.100163en_US
mus.relation.collegeCollege of Engineeringen_US
mus.relation.departmentCenter for Biofilm Engineering.en_US
mus.relation.universityMontana State University - Bozemanen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
haas-endoscopoe-2023.pdf
Size:
1.86 MB
Format:
Adobe Portable Document Format
Description:
lumen biofilm model

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Copyright (c) 2002-2022, LYRASIS. All rights reserved.