Browsing by Author "Ryder, Marcia"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Bacterial transfer and biofilm formation in needleless connectors in a clinically simulated in vitro catheter model(Cambridge University Press, 2023-04) Ryder, Marcia; deLancey-Pulcini, Elinor; Parker, Albert E.; James, Garth A.Objective: Although needleless connectors (NCs) are widely used in clinical practice, they carry significant risk of bloodstream infection (BSI). In this study, we quantified differences in bacterial transfer and biofilm formation between various NCs. Design: Prospective, clinically simulated in vitro experimental study. Methods: We tested 20 NCs in a 5-day clinical simulation of Staphylococcus aureus inoculations onto NC septum surfaces, which were then flushed with saline and cultured for bacterial transfer. Biofilm formation was measured through destructive sampling of the connector-catheter system. Moreover, 8 NC design factors were evaluated for their influence on bacterial transfer and biofilm formation. This study was designed without a disinfection protocol to ascertain the intrinsic risk of each NC. Results: Clave Neutron and MicroClave had the lowest overall mean log density of bacteria in the flush compared to other NCs (P < .05), except there were no statistically significant differences between Clave Neutron, Microclave, SafeTouch, and SafeAccess (P ≥ .05). The amount of biofilm in the NC was positively associated with bacteria in the flush (P < .0005). Among 8 design factors, flow path was most important, with the internal cannula associated with a statistically significant 1 log reduction (LR) in bacteria in the flush (R2 = 49%) and 0.5–2 LR in the connector (R2 = 34%). All factors together best explained bacteria in the flush (R2 = 65%) and biofilm in the connector (R2 = 48%). Conclusions: Bacterial transfer and biofilm formation in the connector-catheter system varied statistically significantly between the 20 NCs, suggesting that NC choice can lower the risk of developing catheter-related BSIs.Item Investigation of the role of infusate properties related to midline catheter failure in an ovine model(2020-08) Ryder, Marcia; Gunther, Robert A.; Nishikawa, Reid A.; Stranz, Marc; Meyer, Britt M.; Spangler, Taylor A.; Parker, Albert E.; Sylvia, CharlesPurpose Infusate osmolarity, pH, and cytotoxicity were investigated as risk factors for midline catheter failure. Methods An experimental, randomized, controlled, blinded trial was conducted using an ovine model. Two 10-cm, 18-gauge single-lumen midline catheters were inserted into the cephalic veins of sheep. The animals were divided into 6 study arms and were administered solutions of vancomycin 4 mg/mL (a low-cytotoxicity infusate) or 10 mg/mL (a high-cytotoxicity infusate), doxycycline 1 mg/mL (an acidic infusate), or acyclovir 3.5 mg/mL (an alkaline infusate) and 0.9% sodium chloride injection; or 1 of 2 premixed Clinimix (amino acids in dextrose; Baxter International) products with respective osmolarities of 675 mOsm/L (a low-osmolarity infusate) and 930 mOsm/L (a mid-osmolarity infusate). Contralateral legs were infused with 0.9% sodium chloride injection for control purposes. Catheter failure was evaluated by assessment of adverse clinical symptoms (swelling, pain, leakage, and occlusion). A quantitative vessel injury score (VIS) was calculated by grading 4 histopathological features: inflammation, mural thrombus, necrosis, and perivascular reaction. Results Among 20 sheep included in the study, the overall catheter failure rate was 95% for test catheters (median time to failure, 7.5 days; range, 3–14 days), while 60% of the control catheters failed before or concurrently (median time to failure, 7 days; range, 4.5–14 days). Four of the 6 study arms (all but the Clinimix 675-mOsm/L and acyclovir 3.5-mg/mL arms) demonstrated an increase in mean VIS of ≥77% in test vs control legs (P ≤ 0.034). Both pain and swelling occurred at higher rates in test vs control legs: 65% vs 10% and 70% vs 50%, respectively. The mean difference in rates of occlusive pericatheter mural thrombus between the test and control arms was statistically significant for the vancomycin 10-mg/mL (P = 0.0476), Clinimix 930-mOsm/L (P = 0.0406), and doxycycline 1-mg/mL (P = 0.032) arms. Conclusion Administration of infusates of varied pH, osmolarity, and cytotoxicity via midline catheter resulted in severe vascular injury and premature catheter failure; therefore, the tested infusates should not be infused via midline catheters.