Evaluation of drinking water biostability using biofilm methods

dc.contributor.authorSharp, Robert R.
dc.contributor.authorCamper, Anne K.
dc.contributor.authorCrippen, J. J.
dc.contributor.authorSchneider, O. D.
dc.contributor.authorLeggiero, S.
dc.date.accessioned2017-11-06T22:44:37Z
dc.date.available2017-11-06T22:44:37Z
dc.date.issued2001-05
dc.description.abstractA biofilm based, annular reactor method was developed and used to measure the biological regrowth potential of effluent water from various pilot treatment processes at the New York City Croton Lake Pilot Plant. A series of studies were carried out over the year-long study to collect bacterial growth and organic carbon biodegradation data for waters from six treatment options, including the raw source water. Quantitative and qualitative evaluations were made to determine the effects of filter media type, direct filtration, preozonation, and primary chlorination on the relative biostability of the produced waters compared to that of the original source water and water currently being distributed to consumers. In addition, results were compared to those obtained using traditional biodegradable organic material measuring methods such as assimilable organic carbon and biodegradable organic carbon. Quantitative biostability factors were developed that take into account both biological growth potential and biodegradability of the tested waters. Results from these studies were used to compare various piloted treatment processes and to assess pilot plant operation, design parameters, and seasonal source water quality.en_US
dc.identifier.citationSharp, R.R., A.K. Camper, J.J. Crippen, O.D. Schneider, and S. Leggiero, "Evaluation of Drinking Water Biostability Using Biofilm Methods," J. Environ. Eng., 403(5):4 (2001).en_US
dc.identifier.issn0733-9372
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/13950
dc.titleEvaluation of drinking water biostability using biofilm methodsen_US
dc.typeArticleen_US
mus.citation.extentfirstpage403en_US
mus.citation.extentlastpage410en_US
mus.citation.issue5en_US
mus.citation.journaltitleJournal of Environmental Engineeringen_US
mus.citation.volume127en_US
mus.data.thumbpage5en_US
mus.identifier.categoryEngineering & Computer Scienceen_US
mus.identifier.doi10.1061/(asce)0733-9372(2001)127:5(403)en_US
mus.relation.collegeCollege of Engineeringen_US
mus.relation.departmentCenter for Biofilm Engineering.en_US
mus.relation.departmentChemical & Biological Engineering.en_US
mus.relation.departmentChemical Engineering.en_US
mus.relation.researchgroupCenter for Biofilm Engineering.en_US
mus.relation.universityMontana State University - Bozemanen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
01-027_Evaluation_of_drinking_.pdf
Size:
137.97 KB
Format:
Adobe Portable Document Format
Description:
Evaluation of drinking water biostability using biofilm methods (PDF)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
826 B
Format:
Item-specific license agreed upon to submission
Description:
Copyright (c) 2002-2022, LYRASIS. All rights reserved.