Checking the validity of the harvesting and disaggregating steps in laboratory tests of surface disinfectants

dc.contributor.authorHamilton, Martin A.
dc.contributor.authorBuckingham-Meyer, Kelli
dc.contributor.authorGoeres, Darla M.
dc.date.accessioned2017-07-12T19:23:48Z
dc.date.available2017-07-12T19:23:48Z
dc.date.issued2009-11
dc.description.abstractA chemical disinfectant against surface-associated bacteria typically uses carriers (e.g., glass disks)that are purposely contaminated with bacteria prior to disinfection. After disinfection, the bacteria are harvested by mechanically separating them from the carrier surface to form a suspension of cells in a dilution tube. Bacterial clumps in the tube are disaggregated using mechanical or chemical techniques, thereby creating a well-mixed suspension of single cells suitable for enumeration. Efficacy is quantified by comparing the viable cell count for a disinfected carrier to the viable cell count for sham-disinfected (control) carrier. A test is said to be biased (invalid) if the observed efficacy measure is systematically higher or lower than the true efficacy. It is shown here for the first time that the bias attributable to the harvesting and disaggregating steps of a disinfectant test can be measured. For some conventional biofilm harvesting and disaggregating techniques, laboratory checks showed either negligible bias or important bias, depending on the disinfectant. Quantitative bias checks on the harvesting and disaggregating steps are prudent for each combination of carrier material, microorganism, and disinfectant. The quantitative results should be augmented by microscopic examination of harvested disinfected and control carriers and of the disaggregated suspensions.en_US
dc.identifier.citationHamilton M, Buckingham-Meyer K, and Goeres DM, "Checking the validity of the harvesting and disaggregating steps in laboratory tests of surface disinfectants," Journal of AOAC International 2009 92(6):1755-1762en_US
dc.identifier.issn1060-3271
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/13232
dc.titleChecking the validity of the harvesting and disaggregating steps in laboratory tests of surface disinfectantsen_US
dc.typeArticleen_US
mus.citation.extentfirstpage1755en_US
mus.citation.extentlastpage1762en_US
mus.citation.issue6en_US
mus.citation.journaltitleJournal of AOAC Internationalen_US
mus.citation.volume92en_US
mus.data.thumbpage6en_US
mus.identifier.categoryEngineering & Computer Scienceen_US
mus.relation.collegeCollege of Engineeringen_US
mus.relation.departmentCenter for Biofilm Engineering.en_US
mus.relation.departmentChemical & Biological Engineering.en_US
mus.relation.departmentChemical Engineering.en_US
mus.relation.researchgroupCenter for Biofilm Engineering.en_US
mus.relation.universityMontana State University - Bozemanen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
09-032_Checking_the_validity_.pdf
Size:
492.24 KB
Format:
Adobe Portable Document Format
Description:
Checking the validity of the harvesting and disaggregating steps in laboratory tests of surface disinfectants (PDF)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
826 B
Format:
Item-specific license agreed upon to submission
Description:
Copyright (c) 2002-2022, LYRASIS. All rights reserved.