Dissolved oxygen and pH microelectrode measurements at water-immersed metal surfaces
dc.contributor.author | Lewandowski, Zbigniew | |
dc.contributor.author | Lee, Whonchee | |
dc.contributor.author | Characklis, William G. | |
dc.contributor.author | Little, Brenda J. | |
dc.date.accessioned | 2017-09-26T17:13:07Z | |
dc.date.available | 2017-09-26T17:13:07Z | |
dc.date.issued | 1989-02 | |
dc.description.abstract | Dissolved oxygen (DO) and pH were measured at metal/artificial seawater interfaces using microelectrodes in biotic and abiotic systems. Measurements in a closed system proved that presence of electrochemical and/or biological reaction products substantially influence the conditions at the metal surface. For long-term studies, only open (e.g., continuous flow) reactors should be used. An open channel flow reactor suitable both for microbiological and electrochemical measurements has been constructed and successfully tested. | en_US |
dc.identifier.citation | Lewandowski Z, Lee W, Characklis WG, Little BJ, "Dissolved oxygen and pH microelectrode measurements at water-immersed metal surfaces," Corrosion. February 1989 45(2):92-98. | en_US |
dc.identifier.issn | 0010-9312 | |
dc.identifier.uri | https://scholarworks.montana.edu/handle/1/13746 | |
dc.title | Dissolved oxygen and pH microelectrode measurements at water-immersed metal surfaces | en_US |
dc.type | Article | en_US |
mus.citation.extentfirstpage | 2 | en_US |
mus.citation.extentlastpage | 92 | en_US |
mus.citation.issue | 2 | en_US |
mus.citation.journaltitle | Corrosion | en_US |
mus.citation.volume | 45 | en_US |
mus.data.thumbpage | 5 | en_US |
mus.identifier.category | Engineering & Computer Science | en_US |
mus.identifier.doi | 10.5006/1.3577838 | en_US |
mus.relation.college | College of Engineering | en_US |
mus.relation.department | Center for Biofilm Engineering. | en_US |
mus.relation.department | Chemical & Biological Engineering. | en_US |
mus.relation.department | Chemical Engineering. | en_US |
mus.relation.researchgroup | Center for Biofilm Engineering. | en_US |
mus.relation.university | Montana State University - Bozeman | en_US |
Files
Original bundle
1 - 1 of 1
- Name:
- 89-005_Dissolved_oxygen_and_pH_microelectrode.pdf
- Size:
- 530.55 KB
- Format:
- Adobe Portable Document Format
- Description:
- Dissolved oxygen and pH microelectrode measurements at water-immersed metal surfaces (PDF)
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 826 B
- Format:
- Item-specific license agreed upon to submission
- Description: