Measurement of local mass transfer coefficient in biofilms

dc.contributor.authorYang, Shunong
dc.contributor.authorLewandowski, Zbigniew
dc.date.accessioned2018-01-30T21:29:52Z
dc.date.available2018-01-30T21:29:52Z
dc.date.issued1995-12
dc.description.abstractLocal mass transfer rates for an electrochemically formed microsink in an aerobic biofilm was measured by a mobile microelectrode using limiting current technique. Mass transfer coefficients varied both horizontally and vertically in the biofilm. The results implied the existence of an irregular biofilm structure consisting of microbial cell clusters surrounded by tortuous water channels. An unexpected increase of the local mass transfer coefficient just above the biofilm surface suggested the existence, of local flow instability in this region. As expected, the influence of bulk flow velocity on the local mass transfer rate decreased with increasing depth into the biofilm. Mass transfer coefficients fluctuated significantly inside microbial cell clusters, suggesting the existence of internal channels through which liquid could flow. A new conceptual model of biofilm microbial cluster structure is proposed to account for such biofilm microstructure irregularities. © 1995 John Wiley & Sons, Inc.en_US
dc.identifier.citationYang, S. and Z. Lewandowski, “Measurement of Local Mass Transfer Coefficient in Biofilms,” Biotechnology and Bioengineering, 48:737-744 (1995).en_US
dc.identifier.issn0006-3592
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/14235
dc.titleMeasurement of local mass transfer coefficient in biofilmsen_US
dc.typeArticleen_US
mus.citation.extentfirstpage737en_US
mus.citation.extentlastpage744en_US
mus.citation.issue6en_US
mus.citation.journaltitleBiotechnology and Bioengineeringen_US
mus.citation.volume48en_US
mus.data.thumbpage5en_US
mus.identifier.categoryEngineering & Computer Scienceen_US
mus.identifier.doi10.1002/bit.260480623en_US
mus.relation.collegeCollege of Engineeringen_US
mus.relation.departmentCenter for Biofilm Engineering.en_US
mus.relation.departmentChemical & Biological Engineering.en_US
mus.relation.departmentChemical Engineering.en_US
mus.relation.researchgroupCenter for Biofilm Engineering.en_US
mus.relation.universityMontana State University - Bozemanen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
95-037_Measurement_of_local_.pdf
Size:
810.03 KB
Format:
Adobe Portable Document Format
Description:
Measurement of local mass transfer coefficient in biofilms (PDF)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
826 B
Format:
Item-specific license agreed upon to submission
Description:
Copyright (c) 2002-2022, LYRASIS. All rights reserved.