Design and fabrication of an automated soil-water micro-sampling system

dc.contributor.advisorChairperson, Graduate Committee: Stephan Warnaten
dc.contributor.authorCollins, Daniel Daviden
dc.date.accessioned2024-12-13T15:10:07Z
dc.date.issued2023en
dc.description.abstractSustainable management of soil nutrients is a challenge for food production to meet the nutritional demands of a growing population of humans, which has surpassed eight billion. Informed management decisions toward maintaining suitable availability of plant macronutrients in soils without excess fertilizer inputs is limited by the ability to collect and analyze water chemistry in small sample volumes extracted from intact soils over time. Additionally, the semi-arid climate and increasingly more frequent meteorological drought conditions in soil systems like the agricultural regions of the Northern Great Plains limit the practicality of conventional soil-water collection and analysis techniques due to the small amounts of water available in the shallow vadose zone during the growing season. In this work, I present progress toward a solution at the intersection of automation, microfabrication, and environmental monitoring systems. The Microfluidic Environmental Solute Analysis (MESA) system has the potential to allow multiple deployments providing enhanced spatial and temporal resolution compared to conventional soil-water collection techniques in measurements of soil water solutes critical to understanding the soil chemistry that supports agricultural production. Using only 100 microliters of water extracted from the soil, the MESA system provides onboard, real-time electrical conductivity analysis (future work will include temperature, pH, and nitrate sensing). The electrical conductivity (EC) sensor uses single-frequency electrochemical impedance spectroscopy (EIS) to measure the bulk fluid resistance within the measurement chamber of the MSM. Calibration of the MSM of EC ranging from 100 - 6440 microseconds cm -1 has shown that the cell constant is 9.530 cm -1, although this parameter is sensor and package dependent. In-situ conductivity measurements in engineered soil columns have revealed that the sand tested has an intrinsic conductivity of approximately 380 microseconds cm -1. The maintenance-free system is intended to be buried in the soil and provide automatic measurements throughout the Montana growing season without being disturbed. The deployment of the MESA system can provide researchers with new data that may enhance our understanding of biogeochemical cycling in dry-land agricultural settings.en
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/18918
dc.language.isoenen
dc.publisherMontana State University - Bozeman, College of Engineeringen
dc.rights.holderCopyright 2023 by Daniel David Collinsen
dc.subject.lcshSoils--Qualityen
dc.subject.lcshWater qualityen
dc.subject.lcshSamplingen
dc.subject.lcshMicrobiologyen
dc.titleDesign and fabrication of an automated soil-water micro-sampling systemen
dc.typeThesisen
mus.data.thumbpage12en
thesis.degree.committeemembersMembers, Graduate Committee: Craig R. Shankwitz; Robert A. Paynen
thesis.degree.departmentMechanical & Industrial Engineering.en
thesis.degree.genreThesisen
thesis.degree.nameMSen
thesis.format.extentfirstpage1en
thesis.format.extentlastpage97en

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
collins-design-2023.pdf
Size:
3.71 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
825 B
Format:
Plain Text
Description:
Copyright (c) 2002-2022, LYRASIS. All rights reserved.