Scholarly Work - Center for Biofilm Engineering
Permanent URI for this collectionhttps://scholarworks.montana.edu/handle/1/9335
Browse
5 results
Search Results
Item Nursing Preference for Alcohol-Based Hand Rub Volume(Cambridge University Press (CUP), 2019-09) Martinello, Richard A.; Arbogast, James W.; Guercia, Kerri; Parker, Albert E.; Boyce, John M.Background:The effectiveness of alcohol-based hand rub (ABHR) is correlated with drying time, which depends on the volume applied. Evidence suggests that there is considerable variation in the amount of ABHR used by healthcare providers. Objective:We sought to identify the volume of ABHR preferred for use by nurses. Methods:A prospective observation study was performed in 8 units at a tertiary-care hospital. Nurses were provided pocket-sized ABHR bottles with caps to record each bottle opening. Nurses were instructed to use the volume of ABHR they felt was best. The average ABHR volume used per hand hygiene event was calculated using cap data and changes in bottle mass. Results:In total, 53 nurses participated and 140 nurse shifts were analyzed. The average ABHR dose was 1.09 mL. This value was greater for non-ICU nurses (1.18 mL) than ICU nurses (0.96 mL), but this difference was not significant. We detected no significant association between hand surface area and preferred average dose volume. The ABHR dose volume was 0.006 mL less per use as the number of applications per shift increased (P = .007).Conclusions:The average dose of ABHR used was similar to the dose provided by the hospital’s automated dispensers, which deliver 1.1 mL per dose. The volume of ABHR dose was inversely correlated with the number of applications of ABHR per shift and was not correlated with hand size. Further research to understand differences and drivers of ABHR volume preferences and whether automated ABHR dosing may create a risk for people with larger hands is warranted.Item Impact of an automated hand hygiene monitoring system and additional promotional activities on hand hygiene performance rates and healthcare-associated infections(2019-07) Boyce, John M.; Laughman, Jennifer A.; Ader, Michael H.; Wagner, Pamela T.; Parker, Albert E.; Arbogast, James W.Objective: Determine the impact of an automated hand hygiene monitoring system (AHHMS) plus complementary strategies on hand hygiene performance rates and healthcare-associated infections (HAIs). Design: Retrospective, nonrandomized, observational, quasi-experimental study. Setting: Single, 93-bed nonprofit hospital. Methods: Hand hygiene compliance rates were estimated using direct observations. An AHHMS, installed on 4 nursing units in a sequential manner, determined hand hygiene performance rates, expressed as the number of hand hygiene events performed upon entering and exiting patient rooms divided by the number of room entries and exits. Additional strategies implemented to improve hand hygiene included goal setting, hospital leadership support, feeding AHHMS data back to healthcare personnel, and use of Toyota Kata performance improvement methods. HAIs were defined using National Healthcare Safety Network criteria. Results: Hand hygiene compliance rates generated by direct observation were substantially higher than performance rates generated by the AHHMS. Installation of the AHHMS without supplementary activities did not yield sustained improvement in hand hygiene performance rates. Implementing several supplementary strategies resulted in a statistically significant 85% increase in hand hygiene performance rates (P < .0001). The incidence density of non–Clostridioies difficile HAIs decreased by 56% (P = .0841), while C. difficile infections increased by 60% (P = .0533) driven by 2 of the 4 study units. Conclusion: Implementation of an AHHMS, when combined with several supplementary strategies as part of a multimodal program, resulted in significantly improved hand hygiene performance rates. Reductions in non–C. difficile HAIs occurred but were not statistically significant.Item Randomized controlled trial evaluating the antimicrobial efficacy of chlorhexidine gluconate and para-chloro-meta-xylenol handwash formulations in real-world doses(2019-06) Arbogast, James W.; Bowersock, Lisa B.; Parker, Albert E.; Macinga, D. R.Chlorhexidine gluconate-based soaps have become the gold standard for handwashing in critical care settings and para-chloro-meta-xylenol is an effective alternative antibacterial active ingredient. This study benchmarked 2 novel foaming handwashes, compared to a bland soap for antimicrobial effectiveness using the health care personnel handwash method at realistic soap doses (0.9 mL and 2.0 mL). To our knowledge, this is the first published efficacy study on realistic soap doses. Both soaps met Food and Drug Administration success criteria.Item Who goes in and out of patient rooms? An observational study of room entries and exits in the acute care setting(2019-05) Arbogast, James W.; Moore, Lori; Clark, Tracy; Thompson, MariaThe objective of this study is to determine what percentage of patient room entries and exits (opportunities) are attributed to health care personnel (HCP) and non-HCP. A total of 14,876 opportunities were observed by clinicians in 29 units of 16 hospitals. HCP accounted for 83.6%; 95% confidence interval, 81.3%-87.6%. This finding provides hospitals an initial baseline for HCP room traffic when implementing community-based automated hand hygiene monitoring and compliance improvement efforts.Item The relative influences of product volume, delivery format and alcohol concentration on dry-time and efficacy of alcohol-based hand rubs(2014-09) Macinga, David R.; Shumaker, David; Werner, Heinz-Peter; Edmonds, Sarah; Leslie, Rachel; Parker, Albert E.; Arbogast, James W.Background Alcohol-based hand rubs (ABHR) range in alcohol concentration from 60-95% and are available in a variety of delivery formats, such as rinses, gels, and foams. Recent studies suggest that some ABHR foams dry too slowly, thereby encouraging the use of inadequate volumes. This study investigates the influence of product volume, delivery format, and alcohol concentration on dry-time and antimicrobial efficacy of ABHR foams, gels and rinses. Methods ABHR dry-times were measured using volunteers to determine the influences of product volume, delivery format, and alcohol concentration. ABHR efficacies were evaluated according to the European Standard for Hygienic Hand Disinfection (EN 1500) using 3-mL application volumes rubbed for 30 s, and additionally, using volumes of the products determined to rub dry in 30 s. Results Volumes of six ABHR determined to rub dry in 30 s ranged from 1.7 mL to 2.1 mL, and the rate of drying varied significantly between products. ABHR dry-times increased linearly with application volume and decreased linearly with increasing alcohol concentration, but were not significantly influenced by product format. An ABHR foam (70% EtOH), rinse (80% EtOH), and gel (90% EtOH) each met EN 1500 efficacy requirements when tested at a volume of 3 mL, but failed when tested at volumes that dried in 30 s. Conclusions Application volume is the primary driver of ABHR dry-time and efficacy, whereas delivery format does not significantly influence either. Although products with greater alcohol concentration dry more quickly, volumes required to meet EN 1500 can take longer than 30 s to dry, even when alcohol concentration is as high as 90%. Future studies are needed to better understand application volumes actually used by healthcare workers in practice, and to understand the clinical efficacy of ABHR at such volumes.