<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Test of 90-Foot Post-Tensioned Concrete Girder with Unbonded Tendons

dc.contributor.authorPujol, Santiago
dc.contributor.authorFick, Damon
dc.contributor.authorFargier-Gabaldón, Luis B.
dc.date.accessioned2022-09-28T20:16:24Z
dc.date.available2022-09-28T20:16:24Z
dc.date.issued2021-09
dc.description.abstractA full-scale post-tensioned concrete girder with unbonded tendons was tested to investigate whether, under vertical forces, a full flexural mechanism (with three hinging regions) would form, and what strand stress would be reached in that condition. The specimen was a 0.91 m (3 ft) deep T-beam with a 2.43 m (8 ft) wide flange, spanning over two supports spaced at 18.3 m (60 ft) with two 4.6 m (15 ft) cantilevers and featured a parabolic tendon profile. Transverse reinforcement to resist shear and longitudinal “mild” reinforcement were also provided. A uniformly distributed load was applied on the main span and concentrated loads were applied to the ends of the cantilevers. While the main span was loaded, the two concentrated loads on the cantilevers provided a reaction force to minimize rotations at supports. At the end of the test, the girder deflected 278 mm (10.9 in., L/65) and carried 231 kN/m (15.5 kip/ft) over the main span. A full plastic mechanism formed with hinging regions at supports and at midspan. Test results suggest the unbonded tendons nearly reached their nominal strength (fpu) and that a limit analysis is adequate for estimating the flexural strength of comparable post-tensioned girders.en_US
dc.identifier.citationPujol, S., Fick, D. R., & Fargier-Gabaldón, L. B. (2021). Test of 90-Foot Post-Tensioned Concrete Girder with Unbonded Tendons. ACI Structural Journal, 118(5).en_US
dc.identifier.issn0889-3241
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/17237
dc.language.isoen_USen_US
dc.publisherAmerican Concrete Instituteen_US
dc.rightscopyright American Concrete Institute 2021en_US
dc.rights.urihttps://www.concrete.org/publications/acimaterialsjournal/writingforacijournals/publicationpolicy.aspxen_US
dc.subjectlimit analysisen_US
dc.subjectpost-tensioned concreteen_US
dc.subjectunbonded tendonsen_US
dc.titleTest of 90-Foot Post-Tensioned Concrete Girder with Unbonded Tendonsen_US
dc.typeArticleen_US
mus.citation.extentfirstpage1en_US
mus.citation.extentlastpage8en_US
mus.citation.issue5en_US
mus.citation.journaltitleACI Structural Journalen_US
mus.citation.volume118en_US
mus.data.thumbpage2en_US
mus.identifier.doi10.14359/51732860en_US
mus.relation.collegeCollege of Letters & Scienceen_US
mus.relation.departmentCivil Engineeringen_US
mus.relation.universityMontana State University - Bozemanen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
pujol-concrete-2021.pdf
Size:
3.48 MB
Format:
Adobe Portable Document Format
Description:
90-foot concrete girder

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
826 B
Format:
Item-specific license agreed upon to submission
Description: