Magnetic resonance microscopy analysis of advective transport in a biofilm reactor

dc.contributor.authorGjersing, Erica L.
dc.contributor.authorCodd, Sarah L.
dc.contributor.authorSeymour, Joseph D.
dc.contributor.authorStewart, Philip S.
dc.date.accessioned2017-07-20T14:41:31Z
dc.date.available2017-07-20T14:41:31Z
dc.date.issued2005
dc.description.abstractIn this article we present magnetic resonance microscopy (MRM) characterization of the advective transport in a biofilm capillary reactor. The biofilm generates non-axial flows that are up to 20% of the maximum axial velocity. The presence of secondary velocities of this magnitude alters the mass transport in the bioreactor relative to non-biofilm fouled reactors and questions the applicability of empirical mass transfer coefficient approaches. The data are discussed in the context of simulations and models of biofilm transport and conceptual aspects of transport modeling in complex flows are also discussed. The variation in the residence time distribution due to biofilm growth is calculated from the measured propagator of the motion. Dynamical systems methods applied to model fluid mixing in complex flows are indicated as a template for extending mass transport theory to quantitatively incorporate microscale data on the advection field into macroscale mass transfer models.en_US
dc.identifier.citationGjersing EL, Codd SL, Seymour JD, Stewart PS, "Magnetic resonance microscopy analysis of advective transport in a biofilm reactor," Biotechnol Bioeng, 2005 89(7):822-834en_US
dc.identifier.issn0006-3592
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/13357
dc.titleMagnetic resonance microscopy analysis of advective transport in a biofilm reactoren_US
dc.typeArticleen_US
mus.citation.extentfirstpage822en_US
mus.citation.extentlastpage834en_US
mus.citation.issue7en_US
mus.citation.journaltitleBiotechnology and Bioengineeringen_US
mus.citation.volume89en_US
mus.contributor.orcidStewart, Philip S.|0000-0001-7773-8570en_US
mus.data.thumbpage7en_US
mus.identifier.categoryEngineering & Computer Scienceen_US
mus.identifier.doi10.1002/bit.20400en_US
mus.relation.collegeCollege of Engineeringen_US
mus.relation.departmentCenter for Biofilm Engineering.en_US
mus.relation.departmentChemical & Biological Engineering.en_US
mus.relation.departmentChemical Engineering.en_US
mus.relation.researchgroupCenter for Biofilm Engineering.en_US
mus.relation.universityMontana State University - Bozemanen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
05-011_Magnetic_resonance_.pdf
Size:
2.77 MB
Format:
Adobe Portable Document Format
Description:
Magnetic resonance microscopy analysis of advective transport in a biofilm reactor (PDF)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
826 B
Format:
Item-specific license agreed upon to submission
Description:
Copyright (c) 2002-2022, LYRASIS. All rights reserved.