A practical method for determining pit depths using X-ray attenuation in EDX spectra

dc.contributor.authorAvci, Recep
dc.contributor.authorDavis, Bret H.
dc.contributor.authorWolfenden, Mark L.
dc.contributor.authorKellerman, Laura R.
dc.contributor.authorLucas, Kilean
dc.contributor.authorMartin, Joshua
dc.contributor.authorDeliorman, Muhammedin
dc.date.accessioned2015-08-16T22:55:55Z
dc.date.available2015-08-16T22:55:55Z
dc.date.issued2015-04
dc.description.abstractA practical method has been developed for rapidly determining the depth of a corrosion micro-pit from the path lengths of X rays passing through the walls of the pit on their way to an X-ray detector. The method takes advantage of the attenuation of the Bremsstrahlung and characteristic X-ray radiation accompanying each X-ray spectrum, and the results are verified independently using AFM and the special pit geometry surrounding MnS inclusions in 1018 carbon steel. The method has general validity and is especially valuable in those cases where the pit depth-to-width ratio is too steep to measure using the conventional methods.en_US
dc.description.sponsorshipONR Multidisciplinary University Research Initiative (MURI) grant N00014-10-1-0946; Montana State University funds supporting the Imaging and Chemical Analysis Laboratory (ICAL)en_US
dc.identifier.citationAvci, Recep, Bret H. Davis, Mark L. Wolfenden, Laura R. Kellerman, Kilean Lucas, Joshua Martin, and Muhammedin Deliorman. A practical method for determining pit depths using X-ray attenuation in EDX spectra. Corrosion Science. April 2015. Pages 9-18.en_US
dc.identifier.issn0010-938X
dc.identifier.urihttps://scholarworks.montana.edu/handle/1/9188
dc.rightsCC BY NC ND Attribution — You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. NonCommercial — You may not use the material for commercial purposes. NoDerivatives — If you remix, transform, or build upon the material, you may not distribute the modified material.en_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/us/legalcodeen_US
dc.subjectPhysicsen_US
dc.subjectOpticsen_US
dc.subjectPitting corrosionen_US
dc.titleA practical method for determining pit depths using X-ray attenuation in EDX spectraen_US
dc.typeArticleen_US
mus.citation.extentfirstpage9en_US
mus.citation.extentlastpage18en_US
mus.citation.journaltitleCorrosion Scienceen_US
mus.citation.volume93en_US
mus.contributor.orcidLucas, Kilean|0000-0002-0058-9850en_US
mus.identifier.categoryPhysics & Mathematicsen_US
mus.identifier.doi10.1016/j.corsci.2014.12.018en_US
mus.relation.collegeCollege of Letters & Scienceen_US
mus.relation.departmentPhysics.en_US
mus.relation.universityMontana State University - Bozemanen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Avci_CorrosionScienc_2015PP_A1b.pdf
Size:
2.21 MB
Format:
Adobe Portable Document Format
Description:
A practical method for determining pit depths using X-ray attenuation in EDX spectra (PDF)