Compact, mid-infrared laser source for remote sensing of gas effluents

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Montana State University - Bozeman, College of Engineering

DOI

Abstract

Remote sensing of gas effluents in the mid-IR wavelength region from 2 microns to 5 microns is preferred due to strong molecular absorption features (10 to 100 times stronger than in the near-IR) and high-transparency atmospheric windows. Currently, long-range mid-IR remote sensing is inhibited by the lack of suitable laser sources. As a result, frequency conversion in nonlinear optical materials has emerged as a powerful method to produce high-power, tunable, mid-IR light. However, compact, high-power narrowband conversion systems suitable for long-range mid-IR spectroscopy are not commercially available. This thesis describes the development of a high-power, narrowband, tunable, compact, mid-IR laser source for long-range remote sensing of gas effluents. Frequency conversion into the mid-IR is achieved by use of a high-peak-power, compact pump laser and optical parametric generation (OPG) in periodically poled nonlinear crystals. This mid-IR laser system was designed and developed for remote sensing at ranges up to and exceeding 100 m in a compact form factor. Such a laser will fill the current scientific need for a hand-held mid-IR laser source capable of long-range mid-IR spectroscopy. Based on theoretical models and experimental demonstrations a compact mid-IR laser source was developed that emits > 1 mJ broadband pulses in the mid-IR. To narrow the linewidth of the broadband OPG output, optical parametric amplification was demonstrated through seeding of the OPG process with a narrowband, continuous-wave, distributed feedback (DFB) laser. Seeding efficiencies exceeding 35% were demonstrated for 1 mJ of output energy, and efficiencies exceeding 65% were demonstrated at lower energies when the pump beam was spatially filtered. The linewidth of the narrowed mid- IR output was inferred to be < 350 MHz based upon heterodyne measurements conducted at the signal wavelength in the near-IR. This linewidth is well within the FWHM bandwidth of typical mid-IR atmospherically broadened molecular absorption features. The demonstrated mid-IR energies and laser linewidths are predicted to be sufficient for detection of low concentration gas effluents (< 1 ppm) at ranges exceeding 100 m. The developed mid-IR laser source was used to successfully demonstrate differential detection of carbon dioxide (CO 2).

Description

Keywords

Citation

Endorsement

Review

Supplemented By

Referenced By

Rights and licensing

Copyright 2009 by Trenton Jeffery Berg